General Scope
The Hitec Metal Pre-Engineered Steel Buildings specified herein shall consist of primary
structure, secondary structure, anchor bolts, girts, bracing, connection clips or as specified.
Primary Structure: Single gable rigid frame, which includes tapered rigid frames, tapered
beams, modular beams and columns; Lean-to rafters and columns; Load bearing posts; and Beam
end frames. Canopy tapered beams and intermediate columns are available if required.
The Secondary Structure: Purlins, girts, eave struts, clips and all other secondary
structural parts.
Framing Members
Welded in factory in accordance with the latest edition of the American Welding Society
(AWS) Code and bolted for assembly. Flanges and webs of built-up members are welded on
one side by continuous automatic submerged arc welding.
Design Code
Designed in accordance to the latest editions of American Institute of Steel Construction
(AISC)- "The Specification for the Design, Fabrication and Erection of Structural Steel
for Building" and the Americal Iron and Steel Institute Code (AISI) - "Specification for
the Design of Light Gauge Cold-formed Steel Structural Members".
Comply with latest British Standard Design (BS5950).
|